product details
Medical waste incinerator
The medical waste incinerator adopts the secondary combustion technology, with one combustion as the main combustion. The materials to be treated (such as medical waste and medical waste) are placed in the incineration bed, and the pathogens are killed at a high temperature of around 1500℃ in the furnace.But at the same time, there will be a pungent smell of the flue gas, and then make the flue gas in the second high temperature combustion chamber completely combustion, high temperature flue gas after
secondary spraying and activated carbon adsorption, to achieve the effect of harmless emissions.
1. It is composed of furnace body, burner, secondary combustion chamber, tail combustion chamber, chimney, control box, blower, etc.
2. Control box: according to the different auxiliary fuel, the control box is divided into fuel wrf-u control box and gas wrf-q control box.
3. Burner: according to different fuels, ju-3 diesel burner and M-12 gas burner are used. Ju-u burner is machine pressure atomization burner. After rotating, the nozzle of burner is ejected from the middle hole at a high number to form atomization state. In rotary air mixed combustion, the air regulating valve of the required air volume is adjusted by the adjusting screw.
4. Secondary combustion chamber and tail combustion chamber: after the combustible gas released from the furnace heat enters the secondary combustion chamber, it is heated and heated up for re combustion, and the auxiliary air is added in the tail combustion chamber to ensure that the combustible gas can be separately burned and burnt out.
5. Intracranial temperature control: the temperature in the furnace is displayed by thermocouple indicator. The temperature control range can be determined by two pointer positions on the indicator, which can be generally adjusted between 400-900 ℃.
2. Control box: according to the different auxiliary fuel, the control box is divided into fuel wrf-u control box and gas wrf-q control box.
3. Burner: according to different fuels, ju-3 diesel burner and M-12 gas burner are used. Ju-u burner is machine pressure atomization burner. After rotating, the nozzle of burner is ejected from the middle hole at a high number to form atomization state. In rotary air mixed combustion, the air regulating valve of the required air volume is adjusted by the adjusting screw.
4. Secondary combustion chamber and tail combustion chamber: after the combustible gas released from the furnace heat enters the secondary combustion chamber, it is heated and heated up for re combustion, and the auxiliary air is added in the tail combustion chamber to ensure that the combustible gas can be separately burned and burnt out.
5. Intracranial temperature control: the temperature in the furnace is displayed by thermocouple indicator. The temperature control range can be determined by two pointer positions on the indicator, which can be generally adjusted between 400-900 ℃.
Pay attention to
Device configuration: The device is not designed in a fixed mode. Can be designed according to different incinerators, site requirements and customer recommendations to meet the safety emission standards.The company's products are: animal body incinerator, food waste disposal, medical waste incinerator and so on.
Practical product cases
Advantage
1) Easy to operate;2) Production and marketing integration;
3) Smokeless and odorless
4) Totally enclosed operation;
5) Suitable for treating infectious waste;
6) Avoid secondery pollution.
1) Easy to operate;2) Production and marketing integration;
3) Smokeless and odorless
4) Totally enclosed operation;
5) Suitable for treating infectious waste;
6) Avoid secondery pollution.
Operation process
1. Check whether there is debris in the incinerator chamber and clean it up;
2. Check whether the oil supply is normal and the output end of the oil tank is open;
3. Check all equipment lines to ensure normal power supply;
4. Ensure the water inflow is normal;
5. Put the crushed medical waste into the furnace, close the furnace door, and tighten the handwheel;
6. Startup process:
Step 1: Open the inlet valve and start the equipment after 3 minutes of normal water supply;
Step 2: Turn the draft fan knob to the open position;
Step 3: Turn the # 1 burner knob to the automatic position;
Step 4: Turn the # 2 burner knob to the open position, at which time the equipment enters normal operation.
7. Incinerate the garbage in the furnace and shut down the equipment after observing that there is no obvious fire or smoke
through the observation mouth;
8. Shutdown process:
Step 1: Turn the # 1 burner knob to the stop position;
Step 2: Turn the # 2 burner knob to the stop position;
Step 3: Turn the draft fan knob to the stop position;
Step 4: Cut off the main power supply of the equipment;
Step 5: Close the inlet valve.
9. After the ash is cooled, clean the ash out of the furnace
3. Check all equipment lines to ensure normal power supply;
4. Ensure the water inflow is normal;
5. Put the crushed medical waste into the furnace, close the furnace door, and tighten the handwheel;
6. Startup process:
Step 1: Open the inlet valve and start the equipment after 3 minutes of normal water supply;
Step 2: Turn the draft fan knob to the open position;
Step 3: Turn the # 1 burner knob to the automatic position;
Step 4: Turn the # 2 burner knob to the open position, at which time the equipment enters normal operation.
7. Incinerate the garbage in the furnace and shut down the equipment after observing that there is no obvious fire or smoke
through the observation mouth;
8. Shutdown process:
Step 1: Turn the # 1 burner knob to the stop position;
Step 2: Turn the # 2 burner knob to the stop position;
Step 3: Turn the draft fan knob to the stop position;
Step 4: Cut off the main power supply of the equipment;
Step 5: Close the inlet valve.
9. After the ash is cooled, clean the ash out of the furnace
Company profile
Henan Yuenai Trading Co., LTD. Is located in Anyang city, Henan Province, China.The company was founded in 2019 with a registered capital of 800,000 yuan.Henan Yuenai Trading Co., LTD. Is an industry and trade integration company, with a professional foreign trade sales team.
The company's goal is to become bigger and stronger, step by step internationalization, to help more customers to make money.
Henan Yuenaitrade Co., Ltd. is the main medical products, the main products are: disposable ligator, disposable laparoscopic puncture, disposable wet heat exchange filter, disposable prepuce stapler, disposable negative pressure drainage bag, disposable medical bed sheet, medical incinerator, muscle vibration instrument and other products, we are also looking forward to working with you.
Henan Yuenaitrade Co., Ltd. is the main medical products, the main products are: disposable ligator, disposable laparoscopic puncture, disposable wet heat exchange filter, disposable prepuce stapler, disposable negative pressure drainage bag, disposable medical bed sheet, medical incinerator, muscle vibration instrument and other products, we are also looking forward to working with you.
Product packaging
FAQ
Q1: Are you trading company or manufacturer ?
Re:We are a company integrating factory and trade
Re:We are a company integrating factory and trade
Q2: How long is your delivery time?
Re:Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q3: What is your terms of payment ?
Re: We support T/T, Western union, Alipay , Paypal, L/C
Q4: Are you provide the after-sales service ?
Re: Yes,we offer one year warranty, and we have a dedicated after-sales service team to provide you with the whole process.
Reviews