Product name
|
Ozone Meter
|
Display method
|
2.8” LCD screen display, 320 x 240 pixels
|
Detection method for PM
|
Electrochemistry
|
Sampling time
|
1.5 seconds
|
Power source
|
Lithium polymer battery with 2000 mAh capacity
|
Product weight
|
500g
|
Product Size
|
164*74*26MM
|
Function
|
Detect O3/Ozone/Ozono/Ozon/Temperature/Humidity
|
Customized service
|
Printing logo, gift box, manual and interface content. Also support wifi service connect Tuya smart app. Zigbee, data save and transfer by USB data line.
|
Quick contact for OEM/Brand service
|
Phone/Wechat/Whatsapp: +86 13602516192 Skype: langder001
|
Detect gas
|
Ozone/Ozono/Ozon(O3) |
||||||
Detection range
|
0.000~5.000ppm |
||||||
Detection principle |
Electrochemistry |
||||||
Response time |
Diffusion ≤15S |
||||||
Duplicate value |
≤±2 %
|
||||||
Resolution
|
0.001ppm
|
||||||
Insulation resistance
|
≥20MΩ
|
||||||
Alarm function
|
Sound(2-3 beep)
|
||||||
Alarm action value
|
0.3/0.6ppm (alarm on/off switchable)
|
-
Product description
self-calibration function.
0~0.100—–Good
-
-
Features:
-
User adjustable alarm threshold for O3 to alert user of elevated
levels
Test variables, temperature, humidity
Large 2000mAh capacity lithium battery
On-board fan to draw in ambient air for more accurate real-time results
5V Micro USB charging
Low battery warning.
-
Operating
-Main device
-USB Charging cable
-User guide
Advantage
concentrations of formaldehyde, total natural & synthetic volatile organic compounds causing most odors (TVOC), and fine particulate dust matter (PM2.5/PM1.0/PM10) which travel
deeply into the respiratory tract, reaching the lung alveoli.
PORTABLE TESTING – Spot check indoor air quality or leave device on for continuous monitoring. Built-in stand allows air monitor to be placed unattended anywhere. This easy-
to-carry device can help monitor air quality at home, in the car, and in hotel rooms. The lithium battery provides portable power when DC 5V micro USB charging is not available.
Information is displayed on a clear 2.8” 320 x 240 pixel color LCD display.
ADVANCED FAN & SENSORS – This air quality monitor has a built-in fan to quickly draw in ambient air to allow REAL-TIME measurements. It incorporates a laser sensor to measure
levels of dust particles and has a second electrochemical semiconductor sensor to measure formaldehyde and natural/synthetic organic compound levels. Air monitor also auto
calibrates in fresh air.
HEALTHY HOME? – Is your family suffering from sick building syndrome? This air quality tester detects organic compounds like formaldehyde which has suspected links to nasal
cancer and lung cancer emitted from many household materials. By measuring particulate pollution, an air pollution monitor can also help you know when asthma may worsen and when
to change your home’s air filter.
ORIGINAL DESIGN & USA BASED SUPPORT – We have Midwest-based technical staff including a chemist to answer any questions you have. Also included will be a 20+ page eBook on Gas
and Air Quality Hazards. We have worked with the supplier that holds this air quality detector’s design rights so you can be confident this item is tried and tested.
A : PM2.5: is main for smog(PM1.0 and PM10 are the same);
HCHO: is for formaldehyde;
TVOC: is main for benzene,etc Volatile organic compounds;
AQI: is for Integrated air quality index.
2. Q: What is the safe range for formaldehyde (HCHO) and TVOC?
A : HCHO≤ 0.10mg / m3
TVOC≤ 0.60mg / m3
According to ("indoor air quality standards" GB / T 18883-2002 and
GB 50325-2001 Class II civil construction).
3 Q: What is the standard range for PM2.5?
A: Good 0~12
Medium 12~35
safe value 35~70
Unhealthy more than 70
4 Q: Why do I need to calibrate(Just HCHO and TVOC need to calibration, PM2.5 and AQI no need)?
A :Our products work in the form of outdoor formaldehyde-free air sampling as a benchmark, and then get indoor air formaldehyde content as a comparison, so the new machine products for a long time not used, the detection of environmental temperature changes, need to calibrated first and then tested, the value of this calibration for the subsequent detection of the accuracy of a great relevance.Calibration environment must avoid spices,perfumes, paint, cigarettes, air fresheners,alcohol and other chemical pollutants, so as not to damage the sensor.
5.Q: Why PM2.5 readings with the published value on the site is not the same?
A : Because the location and conditions of the test is difficult to reconcile with the weather station in the city there are several sampling points, each sampling point measured data are also very different, the sampling point of the location is strictly required; height 3 to 30 meters, air circulation, can not be close to the chimney, furnace and other obvious sources of pollution. And there are no high-rise buildings, trees or other obstructions that can impede the flow of ambient air around the instrument.
6 Q: Why is the PM2.5 test value always changing?
A : PM2.5 data are changing all the times, with the air, wind, humidity and other environmental factors change, in the room smoking, cooking fumes, car exhaust emissions, coal, chimney,furnace Such as pollution sources will change the PM2.5 value of this area, resulting in differences in the detection data.
7 Q: Why does the products make a sound when working?
A : As PM2.5 detection need to collect a lot of mobile air,
the inner fan needs strong operation to ensure accurate detection.
8 Q: How much range of detection of formaldehyde concentration detector,how many square meters?
A : Test area≤ 50m3, room should be set 1~3 testing points;
50m3 ≤ Test area≤ 100m3, room should be set 3~5 testing points;
≥100m3, the points should more than 5 ponits.
Testing points is on a diagonal or plum blossom evenly distributed, would more better.
The height of the sampling point: in principle,consistent with the human breathing.
Relative height of 0.5m ~ 1.5m between.
9 Q: which kinds of air index exceeded, would lead to Alarm sound?
A: Just HCHO data more than 0.10mg / m3, would lead to Beep sound.
Reviews
There are no reviews yet.