NEW Original Made in Taiwan TES -92 EMF Meter Triaxial Data Logger The Electromagnetic Radiation Detector TES92
Features:
- 50 MHz to 3.5 GHz frequency range.
- For isotropic measurements of electromagnetic fields.
- Non-directional (isotropic ) measurement with three-channel measurement probe.
- High dynamic range due to three-channel digital results processing.
- Configurable alarm threshold and memory function.
- Easy to use
|
- High frequency (RF) electromagnetic wave field strength measurement.
- Mobil phone base station antenna radiation power density measurement.
- Wireless communication applications (CW , TDMA , GSM , DECT).
|
- Wireless LAN (Wi-Fi) detection, installation.
- Spy camera, wireless bug finder.
- Cellular/Cordless phone radiation safety level.
- Microwave oven leakage detection.
- Personal living environment EMF safety.
- RF power measurement for transmitters.
|
ELECTRICAL SPECIFICATIONS
|
Sensor type |
Electric field (E) |
Frequency range |
50MHz to 3.5 GHz |
Directional characteristic |
Isotropic, 3-dimensional |
Measurement range (CW signal>50MHz) |
38mV/m to 11V/m |
Absolute error(@1V/m and 50MHz) |
± 1.0dB |
Frequency response (taking into account typ. CAL factor) |
± 1.0dB (50MHz to 1.9 GHz) , ±2.4dB(1.9GHz to 35GHz) |
Isotropy deviation |
Type. ±1.0dB f>50 MHz |
Overload limit |
4.2W/m2 (40 V/m) |
Temperature response(0 to 50 ) |
± 1.5dB |
Note |
Unless otherwise stated, all specifications hold under the following assumptions:
Sinusoidal signals; device in far-field of a source; probe head pointing toward source; ambient temperature +23 ±3 ;relative air humidity 25% to 75%.
|
|
Measurement method
|
Digital , triaxial measurement |
Directional characteristic |
Isotropic, triaxial |
Measurement range selection |
One continuous range |
Display resolution |
0.1mV/m, 0.1 μA/m, 0.1 μW/m², 0.001 μW/cm² |
Setting time |
Typically 1s ( 0 to 90% of meas. value) |
Display refresh rate |
Typically 400mS
|
Display type |
LCD 4 digit |
Audible alarm |
Buzzer |
Measurement units |
mV/m , V/m , μA/m , mA/m , μW/m² , mW/m² , μW/cm² |
Measurement display value |
Instantaneous measured value, maximum value or average value since power-on. |
Measurement average time (in per-set steps) |
4s to 15 minutes |
Measurement alarm function |
Adjustable threshold with ON/OFF |
Measurement calibration factor CAL |
Adjustable |
Manual data memory and read storage |
99 sets ( only recall by meter ) |
Battery |
9V |
Battery life |
>15 hours |
Accessory |
carrying case & manual |
|
Specifications:
Model No.: TES-92 Brand: TES
FEATURES:
0.1dB Resolution
Maximum hold function
AUX OUTPUT JACKS
RS232
Standard applied
|
IEC 651 Type2
|
Range
|
A LO (Low) – Weighting: 35- 100dB A HI (High) – Weighting: 65-130dB C LO (Low) – Weighting: 35- 100dB C HI (High) – Weighting: 65-130dB
|
Resolution
|
0.1dB
|
Frequency Range
|
31.5Hz to 8KHz
|
Accuracy
|
+/- 2dB
|
Dynamic Range
|
65dB
|
Frequency Weighting
|
A C
|
Time Weighting
|
Slow & Fast
|
Maximum Hold
|
Decay < 1dB/3min
|
Microphone
|
Electret condenser microphone
|
Calibration
|
Electrical calibration by using the internal oscillator (1KHz sine Wave at 94dB)
|
Auxilitary Output
|
AC conditioned, 0.65Vrms corresponding to each range step, impedance: 600 W DC conditioned, 10mV/dB (nominally)
|
Operating Condition
|
0 to 40 C< 80% R. H.
|
Storage Condition
|
-10 to 60 C< 70% R.H.
|
Display
|
3 1/2 digitals
|
Power Supply
|
one 9V battery (not included package)
|
Size
|
240mm(L)x68mm(W)x25mm(H)
|
Weight
|
215g
|
Accessorie
|
Instruction Manual, Carrying Case, Screwdriver, Windscreen., Software , Wind shield, RS-232 connecting
|
Reviews