CPN asphalt nuclear density gauge test procedure
The density of asphalt pavement is directly proportional to the dielectric constant of the measured material.The gtj-2701 USES an innovative, spiral-shaped magnetic field detector to test the dielectric constant in the presence of a magnetic field generated by the sensor plate.
The electronic components of the gtj-2701 convert the field signal into a material density reading displayed on the screen.Once the instrument is calibrated, the density can be read at once.
as pictures below:
equipment operation
1.starting up
Turn on the power switch on the left side, the backlight of the display screen of the instrument will flash once, which is also the sound of “drop” of the internal buzzer, and then the instrument will start self-test and start.
2.Menu contents:
After starting up, the instrument displays as follows:
Use the up and down keys to select the corresponding function options. The specific functions are as follows:
< measurement mode >
There are three measurement modes: continuous measurement mode, single measurement mode and average measurement mode
< calibration mode >
There are three calibration modes: normal calibration, one-point calibration and two-point calibration
3. Setting menu
Use the < upper >< lower > arrow, select the last < to set the > option, and then press ok to enter the following interface
4. Ideas
1). Once calibrated, the gtj-2701 can be used for each construction site and asphalt mixture. Recommendations are based on average measurements Method, take 5 or more readings at each construction site.
2). Keep the lower part of the instrument clean and dry. To obtain accurate readings, the contact surface between the instrument and the asphalt shall be clean, dry and flat Slippery. Therefore, the probe surface should be cleaned and dried after each reading.
3) when placing the instrument on the asphalt pavement, check whether there are scattered sundries on the asphalt surface to ensure that the instrument is placed correctly. if The probe surface is formed into asphalt blocks, which are wiped clean with diluent.
4) select a dry test site. Although the instrument has humidity correction function, if the humidity level of the test site is relatively low,You get a more accurate reading. If the test site is visibly wet, it is best to wait for the moisture to evaporate or to wipe dry with a absorbent cloth.
5. Observe suspicious readings
If an abnormal reading is found, check for possible test errors (dirty or wet surface, low voltage) to retake the reading. An accurate reading can be obtained if the humidity remains relatively constant. If the humidity is high or one percentage point below the previous reading, the readings obtained are inaccurate. Do not touch the instrument when testing. Any part of the instrument will affect the reading during the test.
Features | |||||
1 |
The gtj-2701 USES advanced electromagnetic technology to obtain accurate asphalt pavement density readings |
||||
2 |
No special radiation test and certificate are required |
||||
3 |
Easy to use |
||||
4 |
24 hours portable operation |
||||
5 |
Density measured in universal units (Kg./M3) |
||||
6 |
Adjust asphalt temperature |
||||
7 | The internal data recorder can store 4000 readings | ||||
8 | The computer can be loaded at will |
Q: Are your company a trading one or a factory?
A: Factory+ trade (integration), More than 10 years focusing on test instruments field.
Q: After an order is placed, when to deliver?
A: Generally about 10-25days, If we have inventory, we can arrange shipment within 3 days Please be aware that our production lead times depend on specific items and item quantities.
Q: What about the warranty with after-sales services?
A: The testing machine is guaranteed for 12 months by gaotiejian, we can help you to repair your problem con troller freely, even it’s not from our factory. After the warranty, the professional after-sale service team will provide perfect technical support and help guests solve problems encountered while using our product, handles guest problems and complaints in a professional and timely.
Q: What about the product’ services and qualit?
A: Each instruments must be carried out 100% quality examination and test when shipping and delivery goods Product use training, each of our product provide video training to show you how to install operate We can arrange engineer to train the operation of equipment to customer s company when you need. products are widely recognized and trusted by users.