Specifications:
-Measuring Range (mm):0 ~6000mm
-Channels: 100
-Frequency Range (MHz):0.5 ~15MHz
-Material Velocity (m/s): 1000 ~9999m/s
-Vertical Linearity Error: ≤3%
-Horizontal Linearity Error: ≤0.1%
-Sensitivity Leavings: ≥62dB
-Dynamic range: ≥32dB
-Resolving Power: ≥36dB
-Gain (dB): 0 ~100dB
-Measurement Mode: Single,Dual,Thru
-Reject: 0~80%
-Pulse Displacement (μs): -20 ~+3400
-Zero (μs): 0.0 ~99.99
-Port Type: BNC(Q9) or Lemo 01(C9)
-Operating Temperature (℃): -20~70
-H*W*D(mm): 240*156*48
-Weight (kg):1.0(with battery)
Modle size
|
JUT500
|
JUT600
|
JUT800
|
Measuring range
|
0-6000mm
|
0-10000mm
|
0-10000mm
|
Gain
|
0-100dB
|
0-120dB
|
0-130dB
|
D-Delay
|
-20µs~+3400µs
|
-20µs~+3400µs
|
-20µs~+3400µs
|
Resolution
|
0.1mm(2.5mm~100mm) 1mm(>100)
|
0.1mm(2.5mm~100mm) 1mm(>100)
|
0.1mm(2.5mm~100mm) 1mm(>100)
|
P-Delay
|
0µs~99.99µs
|
0µs~99.99µs
|
0µs~99.99µs
|
Material Velocity
|
1000 m/s~9999m/s
|
1000 m/s~15000m/s
|
1000 m/s~15000m/s
|
Temperature
|
-20℃~50℃
|
-20℃~50℃
|
-20℃~50℃
|
Humidity
|
20%~90%RH
|
20%~90%RH
|
20%~90%RH
|
Power
|
7.4V 4800mAh
|
7.4V 4800mAh
|
7.4V 4800mAh
|
Working time
|
>8 hours
|
>10 hours
|
>10 hours
|
Display
|
LED true color
|
LED true color
|
LED true color
|
Size
|
238mm*160mm*50mm
|
238mm*160mm*50mm
|
238mm*160mm*50mm
|
Weight
|
1.0kg
|
1.0kg
|
1.0kg
|
Main Features
*Automated calibration of transducer Zero Offset aor Velocity;
*Automated gain, Peak Hold and Peak Memory;
*Automated display precise flaw location(Depth d,level p,distance s,amplitude,sz dB,ф);
*Automated switch (Depth d,level p,distance s);
*100 independence setup,any criterion can be input freely, we can work in the scene without test block;
*Big memory of 300 A graph.
*Gate and DAC alarm;Acoustic-Optical alarm;
*RS232/USB port, easy to connect with pc;
*The embeded software can be online updated;
*Li battery, continue working time up to 10 hours;
*Display freeze;
*Automated echo degree;
*Angles and K-value;
*Lock and unlock function of system parameters;
*Electronic clock calendar ;
*Two gates setting and alarm indication;
*High-speed capture and very low noise;
*DAC,AVG; Solid metal housing;
*Automated calculate the size of the flaw with w ide bottom type in AVG function.
No.
|
Item
|
Notes
|
1
|
All kinds of straight beam probe
|
Please confirm with us
|
2
|
All kinds of angle probe
|
Please confirm with us
|
3
|
Calibration block
|
IIW(V1);
IIW Ⅱ(V2);
DSC,DC,SC
|
4
|
Cable
|
All kinds of connectors' cables( BNC, Lemo, and Microdot
|
Standard configuration
Item
|
Name
|
QTY
|
1
|
Main Unit
|
1
|
2
|
1.5A/9V power adaptor
|
1
|
3
|
probe connecting cable
|
2
|
4
|
Instrument case
|
1
|
5
|
Instruction manual
|
1
|
6
|
Straight probe 10mm 4MHz
|
1
|
7
|
Angle probe 8×9 60°4MHz
|
1
|
8
|
Warranty card
|
1
|
Reviews