1. Test function
★ Waveform real-time display (4 channels voltage/4 channels current).
★ True RMS values of voltages and currents.
★ The DC components of voltages.
★ Peak current and voltage values.
★ Minimum and maximum half-cycle RMS current and voltage values.
★ Pharos diagram display.
★ Measurement of each harmonic up to order 50.
★ Bar charts show harmonic ratios of current and voltage of each phase.
★ Total harmonic distortion (THD).
★ Active, reactive, apparent power, by phase and cumulative.
★ Active, reactive, apparent energy, by phase and cumulative.
★ Transformer K factor.
★ Power factors (PF) and displacement factors (DPF or COSΦ).
★ Short-term voltage flicker (PST).
★ Three phase unbalance(current and voltage).
2. Transientcapture function
Monitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctuations, voltage
current surge, sag and short supply interruption, temporary overvoltage, impact current and Current voltage instantaneous
distortion. Instruments can store 150 sets of transient waveform at the same time.
3. Starting current monitoring
Monitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity.
Can be display the RMS rising / falling curve In the startup process, the envelope curve of startup current, waveform of 4
channels current and 4 channels voltage. Recording about 100s after trigger, storage the current /voltage instantaneous and
waveform curve of each cycle in 100s.
4. Trend chart recording and storing function
Store all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf,
Aunb, KF,W, VAR, VA, PF, COSφ, TANφ),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a
long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).
5. Alarm function
Set the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as:
voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distortion. You can configure 40 different
alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit
values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.
6. Snapshot function
Any screen can be saved (screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage
and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.
7. Communication function
Communicate with computer via USB; Monitoring software can display waveform of power quality analysis, read of the transient
waveform, trend chart recording, alarm log, screenshots, and display on the computer.
The user can configuration of the time and date, configuration of the screen contrast and brightness, definition of each phase
curve colors’.
Choice of type of connection to the net work.
Configuration of the type of the current sensors and voltage ratios.
Select Chinese menu or English menu.
Every stage of operation can press the “help” key to obtain relevant information.
Measurement
|
Range
|
Display resolution
|
The maximum error in the range of the reference
|
Frequency
|
40Hz~ 70Hz
|
0.01Hz
|
±(0.03)Hz
|
True RMS phase-to-neutral voltage
|
1.0V~ 1000V
|
Min resolution 0.1V
|
±(0.5%+5dgt)
|
True RMS phase-to phase voltage
|
1.0V~ 2000V
|
Min resolution 0.1V
|
±(0.5%+5dgt)
|
DC voltage
|
1.0V~ 1000V
|
Min resolution 0.1V
|
±(1.0%+5dgt)
|
True RMS current
|
10mA~ 6000A
|
Min resolution 1mA
|
±(0.5%+5dgt)
|
Peak of phase-to-neutral voltage
|
1.0V~ 1414V
|
Min resolution 0.1V
|
±(1.0%+5dgt)
|
Peak of phase-to-phase voltage
|
1.0V~ 2828V
|
Min resolution 0.1V
|
±(1.0%+5dgt)
|
Current peak
|
10mA~ 8484A
|
Min resolution 1mA
|
±(1.0%+5dgt)
|
Peak factor
|
1.00~ 3.99
|
0.01
|
±(1%+2dgt)
|
4.00~ 9.99
|
0.01
|
±(5%+2dgt)
|
|
Active power
|
0.000W~ 9999.9kW
|
Min resolution 0.001W
|
±(1%+3dgt)
Cosφ≥0.8 |
±(1.5%+10dgt)
0.2≤Cosφ<0.8 |
|||
Reactive power, inductive or capacitive
|
0.000VAR~
9999.9kVAR |
Min resolution 0.001VAR
|
±(1%+3dgt)
Sinφ≥0.5 |
±(1.5%+10dgt)
0.2≤Sinφ<0.5 |
|||
Apparent power
|
0.000VA~
9999.9kVA |
Min resolution 0.001VA
|
±(1%+3dgt)
|
Power factor
|
-1.000~ 1.000
|
0.001
|
±(1.5%+3dgt)
Cosφ≥0.5 |
±(1.5%+10dgt)
0.2≤Cosφ<0.5 |
|||
Active energy
|
0.000Wh~ 9999.9MWh
|
Min resolution 0.001Wh
|
±(1%+3dgt)
Cosφ≥0.8 |
±(1.5%+10dgt)
0.2≤Cosφ<0.8 |
|||
Reactive energy, inductive or capacitive
|
0.000VARh~ 9999.9MVARh
|
Min resolution 0.001VARh
|
±(1%+3dgt)
Sinφ≥0.5 |
±(1.5%+10dgt)
0.2≤Sinφ<0.5 |
|||
Papparent energy
|
0.000VAh~ 9999.9MVAh
|
Min resolution 0.001VAh
|
±(1%+3dgt)
|
Phase angle
|
-179°~ 180°
|
1°
|
±(2°)
|
Tanφ
(VA≥50VA) |
-32.76~ 32.76
|
Min resolution 0.001
|
φ:±(1°)
|
Phase shift of power factor (DPF)
|
-1.000~ 1.000
|
0.001
|
φ:±(1°
|
Harmonic ratio
(order 1 to 50) (Vrms>50V) |
0.0%~ 99.9%
|
0.1%
|
±(1%+5dgt)
|
Harmonic angle
(Vrms>50V) |
-179°~ 180°
|
1°
|
±(3°) harmonics of order 1 to 25
|
±(10°) harmonics of order 26 to 50
|
|||
Total harmonic ratio
(THD or THD-F)≤50 |
0.0%~ 99.9%
|
0.1%
|
±(1%+5dgt)
|
Distortion factor
(DF or THD-R)≤50 |
0.0%~ 99.9%
|
0.1%
|
±(1%+10dgt)
|
Transformer K factor
|
1.00~ 99.99
|
0.01
|
±(5%)
|
3 phases unbalance
|
0.0%~ 100%
|
0.1%
|
±(1%)
|
Type of current sensor
|
True RMS current
|
Max error of true RMS current
|
Max error of phase angleφ
|
FR008 current clamp
|
10mA~ 99mA
|
±(1%+3dgt)
|
±(1.5°),Arms≥20mA
|
100mA~ 10.0A
|
±(1%+3dgt)
|
±(1°)
|
|
FR020 current clamp
|
0.10A~ 0.99A
|
±(1%+3dgt)
|
±(1.5°)
|
1.00A~ 100A
|
±(1%+3dgt)
|
±(1°)
|
|
FR050 current clamp
|
1.0A~ 9.9A
|
±(2%+3dgt)
|
±(3°)
|
10.0A~ 1000A
|
±(2%+3dgt)
|
±(2°)
|
|
FR300R Flexible Coil Current Sensor (with Integrator)
|
10A~199A
|
±(1 % + 3dgt)
|
±(3°)
|
200A~6000A
|
±(1 % + 3dgt)
|
±(2°)
|
online monitoring equipment, portable electrical measuring instruments.ZhengNeng in line with scientific and technological
innovation, people-oriented principle for many years has been recognized by customers. The company has professional technical
team, and cooperat with Guangzhou major university, scientific research institutes, to provide high-quality products and perfect
after-sales service to the national electric power industry.
Company’s main products are power quality monitor, field calibration meter, phase volt ampere meter, relay protection test
instrument, clamp power meter, grounding resistance tester, grounding fault tester,insulation resistance tester, high voltage
current clamp meter, high voltage CT ratio tester, loop resistance tester, DC resistance tester, leakage protection testing
instrument and other products.
Our company has professional technical team and strict quality control system,and has passed ISO9001:2008 quality system
authenticatio,adhere to scientific and technological innovation, excellence, mutual benefit and win-win business spirit to seek
greater development.
We can accept Bank Transfer, Paypal, Western Union, Money Gram, Cash etc.
2. Delivery time:
Within 15 workdays after confirmed payment(base on the quantity you order)
3. MOQ:
Small order is also welcome.
4. Contact us:
Please don’t hesitate to contact us if you have any questions or concerns before or after your purchase
All the inquiries will be replied within 24 hours.
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
Reviews
There are no reviews yet.