* iPhone/iPad/Android/Windows Oscilloscope, Multi-touch Operation.
* WIFI Communication (USB Communication), WIFI Direct Connection/ Router Connection.
* Build-in Lithium Battery , no need of External Power. Floating Measurement is available, safe and convenient.
* 70MHz Bandwidth, Real-time Sampling Rate 250MSa/s
* Can be connected with iPad and iPhone at the same time. When operating on iPad, it can also be observed on iPhone.
* Good mechanical design. The outer case is made by the same material with iPad – Anodised aluminium. It has great heat
resistance and abrasive resistance with beautiful appearance. The hardness of aluminium alloy surface is greatly improved
* Small size which is convenient for traveling.
* Software Support:IOS,Android(Partial function),Win10,Win8, Win7, VISTA, etc.
* More than 20 kinds of automatic measurement function, PASS/FAIL Check function, fit for engineering application.
* FFT spectrum analyzer
* Waveform averaging, afterglow, lightness control, reverse, add, subtract, multiply, divide, X-Y display.
* The waveform data can be output as EXCEL, BMP, JPG according to time and voltage.
Model
|
iDSO1070A
|
||||||
Bandwidth
|
70MHz
|
||||||
Channel
|
2 CH
|
||||||
Real-time Sampling Rate
|
250MSa/s (single channel), 125MSa/s (two channels)
|
||||||
Sampling Mode
|
Sampling, Vmax, Vrms
|
||||||
Average Sampling
|
Average waveform, times: 4, 8, 16, 32, 64, 128
|
||||||
Memory Depth
|
6K
|
||||||
Rise time
|
≤5ns
|
||||||
Time Base Precision
|
±50ppm
|
||||||
Time Base Range
|
45s/div-500s/div (1-2-4 sequences)
|
||||||
Input Coupling
|
DC, AC, GND
|
||||||
Input Impedance
|
Resistance: 1MΩ; Capacitance:25pF
|
||||||
Probe Attenuation Coefficient Setting
|
1×, 10×, 100×, 1000
|
||||||
Max Input Voltage
|
35Vpk(DC+peak)
|
||||||
Waveform Interpolation
|
Step, Linear, Sin(x)/x
|
||||||
Input Sensitivity
|
10mV/div~5V/div
|
||||||
Vertical Resolution
|
8Bit
|
||||||
Vertical Displacement Range
|
10mV ~ 5V/div @ x1 probe; 100mV ~ 50V/div @ x10 probe;
|
||||||
1V ~ 500V/div @ x100 probe; 10V ~ 5KV/div @ x1000 probe
|
|||||||
Position Range
|
±4division
|
||||||
Low Frequency Response
|
≤10Hz (at input BNC)
|
||||||
DC Gain Accuracy
|
±3%
|
||||||
Bandwidth Limit
|
20MHz
|
||||||
Trigger Mode
|
Auto, normal, single
|
||||||
Trigger Type
|
Edge, Alternative
|
||||||
Trigger Precision
|
±4division
|
||||||
Trigger Range
|
±4V
|
||||||
Trigger Sensitivity
|
0.02 division
|
||||||
Trigger Source
|
CH1, CH2, EXT
|
||||||
Waveform Signal Process
|
+,-,x,÷,FFT, invert
|
||||||
Temperature
|
Operating: 0℃-40℃; Non-operating: -20℃-60℃
|
||||||
Humidity
|
Below 35℃, ≤90% relative humidity; 35℃-40℃, ≤60% relative humidity
|
||||||
Cursors Measurement
|
Cross, Trace, Horizontal, Vertical
|
||||||
Auto Measurement
|
Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time,
Positive Width, Negative Width, Duty Cycle |
||||||
Volume
|
190mm * 100mm * 35mm
|